// DEVICE-SPECIFIC LED SERVICES //
|
|
////////////////////////////////////
|
|
|
|
struct DEV_LED : Service::LightBulb {
|
|
|
|
int ledPin;
|
|
SpanCharacteristic *power;
|
|
|
|
DEV_LED(int ledPin) : Service::LightBulb(){
|
|
|
|
power=new Characteristic::On();
|
|
this->ledPin=ledPin;
|
|
pinMode(ledPin,OUTPUT);
|
|
WEBLOG("Configuring LED on Pin %d",ledPin); // NEW! This creates a Web Log message announcing the configuration of the device
|
|
|
|
} // end constructor
|
|
|
|
boolean update(){
|
|
|
|
digitalWrite(ledPin,power->getNewVal());
|
|
WEBLOG("LED on Pin %d: %s",ledPin,power->getNewVal()?"ON":"OFF"); // NEW! This creates a Web Log message whenever an LED is turned ON or OFF
|
|
return(true);
|
|
|
|
} // update
|
|
};
|
|
|
|
//////////////////////////////////
|
|
|
|
// SOME MORE ABOUT WEB LOGGING
|
|
// ---------------------------
|
|
//
|
|
// * The WEBLOG() macro operates by calling Serial.printf(), so the first argument always needs to be a text string containing printf-like format instructions.
|
|
// The rest of the arguments, if any, are the variables to print. For example, you cannot simply write WEBLOG(ledPin). This will cause errors at compile time,
|
|
// though you can write LOG1(ledPin) or LOG2(ledPin) to output log messages just to the Serial Monitor.
|
|
//
|
|
// * You do NOT need to include a "\n" at the end of your format string since all Web Log messages are formatted into an HTML table when presented, and HTML ignores "\n".
|
|
//
|
|
// * Every Web Log message is recorded with TWO timestamps. The first timestamp is relative to when the device first booted, and is presented as DAYS:HH:MM:SS. This timestamp
|
|
// is always present. The second timestamp is an absolute clock time, in standard Unix form, such as "Mon Aug 10 13:52:48 2020". This timestamp will only be present
|
|
// if the clock time of the device was set, else it will be shown as "Unknown". Note that in the example above, the first Web Log message ("Configuring...") will
|
|
// have a clock timestamp of "Unknown" even though we enabled Web Logging with a Time Server. This is because the Time Server cannot be configured until WiFi has
|
|
// been established, and the first Web Log message above is created during initial configuratin of the device, BEFORE a WiFi connection is made. This is perfectly fine to do.
|
|
//
|
|
// * Every Web Log message also includes the IP Address of the Client that made the request, unless the Web Log message was generated independently of any Client request,
|
|
// such as in the first message above. In these cases the IP Address will be displayed as 0.0.0.0.
|
|
//
|
|
// * Web Log messages are printed to the Serial Monitor whenever the HomeSpan Log Level is set to 1 or greater. Hence there is no reason to duplicate the same message
|
|
// using WEBLOG() and LOG1() at the same time.
|